initial commit

This commit is contained in:
2025-10-17 09:29:37 +03:00
commit 9739ede62e
25 changed files with 2270 additions and 0 deletions

View File

@@ -0,0 +1,112 @@
package collector
import (
"context"
"fmt"
"log"
"strconv"
"time"
"gitea.sinav-lab.com/sinav/keenetic-exporter-v2/internal/device"
"gitea.sinav-lab.com/sinav/keenetic-exporter-v2/internal/keenetic"
"github.com/prometheus/client_golang/prometheus"
)
type SystemCollector struct {
cpuLoadDesc *prometheus.Desc
memTotalDesc *prometheus.Desc
memFreeDesc *prometheus.Desc
memCacheDesc *prometheus.Desc
memBuffersDesc *prometheus.Desc
swapTotalDesc *prometheus.Desc
swapFreeDesc *prometheus.Desc
connTotalDesc *prometheus.Desc
connFreeDesc *prometheus.Desc
uptimeDesc *prometheus.Desc
}
func NewSystemCollector() *SystemCollector {
labels := []string{"device"}
return &SystemCollector{
cpuLoadDesc: prometheus.NewDesc("keenetic_cpu_load", "Current CPU load", labels, nil),
memTotalDesc: prometheus.NewDesc("keenetic_memory_total_bytes", "Total memory in bytes", labels, nil),
memFreeDesc: prometheus.NewDesc("keenetic_memory_free_bytes", "Free memory in bytes", labels, nil),
memCacheDesc: prometheus.NewDesc("keenetic_memory_cache_bytes", "Cache memory in bytes", labels, nil),
memBuffersDesc: prometheus.NewDesc("keenetic_memory_buffers_bytes", "Buffer memory in bytes", labels, nil),
swapTotalDesc: prometheus.NewDesc("keenetic_swap_total_bytes", "Total swap in bytes", labels, nil),
swapFreeDesc: prometheus.NewDesc("keenetic_swap_free_bytes", "Free swap in bytes", labels, nil),
connTotalDesc: prometheus.NewDesc("keenetic_connections_total", "Total number of connections", labels, nil),
connFreeDesc: prometheus.NewDesc("keenetic_connections_free", "Number of free connections", labels, nil),
uptimeDesc: prometheus.NewDesc("keenetic_uptime_seconds", "Device uptime in seconds", labels, nil),
}
}
func (c *SystemCollector) Name() string {
return "system"
}
func (c *SystemCollector) Describe(ch chan<- *prometheus.Desc) {
ch <- c.cpuLoadDesc
ch <- c.memTotalDesc
ch <- c.memFreeDesc
ch <- c.memCacheDesc
ch <- c.memBuffersDesc
ch <- c.swapTotalDesc
ch <- c.swapFreeDesc
ch <- c.connTotalDesc
ch <- c.connFreeDesc
ch <- c.uptimeDesc
}
func (c *SystemCollector) Collect(dev *device.Device, ch chan<- prometheus.Metric) error {
var sysInfo any
var ok bool
hostname := dev.Name
client := dev.Client
dev.CacheMutex.RLock()
sysInfo, ok = dev.Cache["system"]
valid := time.Since(dev.LastUpdate) < dev.CacheTTL
dev.CacheMutex.RUnlock()
if !ok || !valid {
ctx, cancel := context.WithTimeout(context.Background(), 10*time.Second)
fresh, err := client.GetSystemInfo(ctx)
cancel()
if err != nil {
log.Printf("Failed to get system info from %s: %v", hostname, err)
return err
}
sysInfo = fresh
dev.CacheMutex.Lock()
dev.Cache["system"] = fresh
dev.LastUpdate = time.Now()
dev.CacheMutex.Unlock()
}
s, ok := sysInfo.(*keenetic.SystemInfo)
if !ok || s == nil {
log.Printf("invalid cache data type for system info on %s", hostname)
return fmt.Errorf("invalid cache data type for system info")
}
uptime, err := strconv.ParseFloat(s.Uptime, 64)
if err != nil {
log.Printf("failed to parse uptime for %s: %v", hostname, err)
return fmt.Errorf("failed to parse uptime: %w", err)
}
ch <- prometheus.MustNewConstMetric(c.cpuLoadDesc, prometheus.GaugeValue, s.CpuLoad, hostname)
ch <- prometheus.MustNewConstMetric(c.memTotalDesc, prometheus.GaugeValue, s.MemTotal, hostname)
ch <- prometheus.MustNewConstMetric(c.memFreeDesc, prometheus.GaugeValue, s.MemFree, hostname)
ch <- prometheus.MustNewConstMetric(c.memCacheDesc, prometheus.GaugeValue, s.MemCache, hostname)
ch <- prometheus.MustNewConstMetric(c.memBuffersDesc, prometheus.GaugeValue, s.MemBuffers, hostname)
ch <- prometheus.MustNewConstMetric(c.swapTotalDesc, prometheus.GaugeValue, s.SwapTotal, hostname)
ch <- prometheus.MustNewConstMetric(c.swapFreeDesc, prometheus.GaugeValue, s.SwapFree, hostname)
ch <- prometheus.MustNewConstMetric(c.connTotalDesc, prometheus.GaugeValue, s.ConnTotal, hostname)
ch <- prometheus.MustNewConstMetric(c.connFreeDesc, prometheus.GaugeValue, s.ConnFree, hostname)
ch <- prometheus.MustNewConstMetric(c.uptimeDesc, prometheus.CounterValue, uptime, hostname)
return nil
}